Ürün Özellikleri:
%2 doğrulukla hassas ölçümler Kısa tepki süresi (15 sn) Medya algılama ve farklılaştırma için ideal Kolay devreye alma için IO-Link Çift Kanal
Performance characteristics conductivity; Min. measurable conductivity 1 µS/cm Max. measuring span 1000 mS/cm Max. measuring error ≤ ± 2.0 % MV ± 15 µS/cm Reference temperature 25 °C , adjustable Repeatability ≤ ± 1.0 % MV ± 10 µS/cm Compensated temperature range -20 … 150 °C Temperature compensation 0.0 … 5.0 %/K , adjustable Step response time, T90 ≤ 1.5 s Sample time ≤ 0.4 s Performance characteristics concentration; Concentration Programmable with IO-Link and FlexProgram Factory set media (available from FlexProgram) 0 … 25 % by weight , HNO3 (nitric acid) 36 … 82 % by weight , HNO3 (nitric acid) 0 … 12 % by weight , NaOH (caustic soda) 25 … 50 % by weight , NaOH (caustic soda) Customer defined media Customer defined (30 point lookup table) Input damping 0 … 30 s , programmable Performance characteristics temperature; Measuring range -25 … 150 °C Thermal response time, T90 ≤ 15 s Max. measuring error ± 1.5 K ± 0.3 K , 20 … 50 °C
Internet Explorer tarayıcısının 9.0 ve daha eski sürümlerini desteklememekteyiz. Web sitemizi doğru görüntüleyebilmek için tarayıcınızı güncelleyebilirsiniz, güncelleyemiyorsanız başka bir tarayıcıyı ücretsiz yükleyebilirsiniz.